Three points for attention in the use of reducer
【2017-10-25】
1. No hammering
Install the coupling, the output shaft pulley, sprocket and other methods can not be used directly when the connection piece hammer, because the output shaft of the speed reducer structure can not bear the axial hammer shaft end of the screw is screwed into the screw can be suppressed into the connecting piece.
2, must be installed in the ventilation cap (exhaust plug)
Before use should be put on the high exhaust plug plug at the discharge gas in the reducer running guarantee. If it is not replaced in time, the operation time of the governor will be reduced, and the gas in the reducer will cause the oil seal to swell and the oil leakage of the reducer.
3, timely replacement of lubricating oil, pay special attention to the first time
Special attention should be paid to the first oil change, the reducer should be replaced immediately after the first operation 300~400 hours, and then replace the lubricating oil every 1500~2000 hours. In addition, poor working environment and high temperature, dust and work situations should be every half a month to conduct an inspection of lubricating oil, lubricating oil contamination is found to replace oil, lubricating oil to keep clean, prolong the life of gear reducer, improve economic efficiency.